Rubber material

no image
VALQUA No.
B5075
Features, applications
Lubricated, nonadhesive

Product
O-ring, various seals
Hardness durometer A
75
Tensile strength MPa
19.0
Expansion %
290
Compression permanent set %
15
Compression permanent set test conditions
3)120℃-70h
Applicable standards
Public Notice of the Ministry of Health, Labor and Welfare No. 201 / JIS K6353

Symbol of the same type of material
Note
Please let us know if you are placing an order for food application.

■ Available ranges

Temperature ℃
-25〜+150

■ FAQ